DRYPOINT RAx Click for Larger View

Call us TODAY at 727-835-0670 or
Toll Free at 800-761-4298

Get A Free Quote!

BEKO DRYPOINT® RAx

Required pre-filtration: 1 μm | Recommended post-filtration: .01 μm
• RAx 20-200 115V UL / CSA certified
• RAx 125-400 230V UL / CSA certified
• Outlet pressure dew point: Class 4-5 in accordance with ISO 8573-1:2010
• Max. inlet air temperature: 160 °F
• Min. / max. ambient temperature: 34 °F / 120 °F
• Max. inlet pressure: RAx 20-50: 232 psig | RAx 75-500: 200 psig

Maintenance Interval:   < 8,000 hours
Maintenance Kits & Spare Parts

Click Here for Correction Factor Charts


Operating Pressure psig 60 80 100 120 140 160 180 200
Correction Factor .79 .91 1.00 1.07 1.13 1.18 1.23 1.27

Ambient Air Temperature °F 80 90 100 105 110 115 120
Correction Factor 1.11 1.09 1.00 .94 .87 .78 .69

Inlet Air Temperature °F 90 100 110 120 130 140 150 160
Correction Factor 1.16 1.00 .82 .68 .61 .52 .45 .40
The correction factors on this page provide an estimation of the performance that can be achieved with the model sizes shown. For precise sizing for your application, please contact your MDI sales representative.
*Scroll to the right on mobile to see entire chart
  Quantity Add to
Quote
DRYPOINT® RAx
Connection Size
(NPT)
Flow Rate
(scfm)
Power Consumption -
Load (kW)
Standard
Operating
Voltage
RAx 20
½"
20
.26
115 V / 1 Ph
RAx 30
½"
30
.27
115 V / 1 Ph
RAx 50
½"
50
.39
115 V / 1 Ph
RAx 75
1"
75
.48
115 V / 1 Ph
RAx 100
1¼"
100
.58
115 V / 1 Ph
RAx 125
1¼"
125
1.00
115 V / 1 Ph
RAx 150
1¼"
150
1.05
115 V / 1 Ph
RAx 200
1½"
200
1.10
115 V / 1 Ph
  Quantity Add to
Quote
DRYPOINT® RAx
Connection Size
(NPT)
Flow Rate
(scfm)
Power Consumption -
Load (kW)
Optional
Operating
Voltage
RAx 20
½"
20
.26
230 V / 1 Ph
RAx 30
½"
30
.27
230 V / 1 Ph
RAx 50
½"
50
.39
230 V / 1 Ph
RAx 75
1"
75
.48
230 V / 1 Ph
RAx 100
1¼"
100
.58
230 V / 1 Ph
RAx 125
1¼"
125
1.00
230 V / 1 Ph
RAx 150
1¼"
150
1.05
230 V / 1 Ph
RAx 200
1½"
200
1.10
230 V / 1 Ph


*Scroll to the right on mobile to see entire chart
  Quantity Add to
Quote
DRYPOINT® RAx
Connection Size
(NPT)
Flow Rate
(scfm)
Power Consumption -
Load (kW)
Standard
Operating
Voltage
RAx 200
1½"
200
1.10
Optional - 230 V / 1 Ph
RAx 250
1½"
250
1.39
230 V / 1 Ph
RAx 300
2"
300
1.64
230 V / 1 Ph
RAx 350
2"
350
2.19
230 V / 1 Ph
RAx 400
2½"
400
2.48
230 V / 1 Ph
  Quantity Add to
Quote
DRYPOINT® RAx
Connection Size
(NPT)
Flow Rate
(scfm)
Power Consumption -
Load (kW)
Optional
Operating
Voltage
RAx 200
1½"
200
1.10
460 V / 3 Ph
RAx 250
1½"
250
1.39
460 V / 3 Ph
RAx 300
2"
300
1.64
460 V / 3 Ph
RAx 350
2"
350
2.19
460 V / 3 Ph
RAx 400
2½"
400
2.48
460 V / 3 Ph
RAx 500
2½"
500
2.97
Standard - 460 V / 3 Ph



*Scroll to the right on mobile to see entire chart
REQUIRED 1 μm PRE-FILTRATION
without Δpsi gauge | Float Drain
with Δpsi gauge | BEKOMAT®
RAx 20
4020220
4020251
RAx 30
4020220
4020251
RAx 50
4002891
4017447
RAx 75
4020305
4020404
RAx 100
4020305
4020404
RAx 125
4020305
4020404
RAx 150
4002894
4014546
RAx 200
4002896
4016192
RAx 250
4002896
4016192
RAx 300
4002898
4006657
RAx 350
4002898
4006657
RAx 400
4002901
4014908
RAx 500
4002901
4014908

*Scroll to the right on mobile to see entire chart
OPTIONAL .01 μm POST-FILTRATION
Post-Filter | .01 μm
RAx 20
4020231
RAx 30
4020231
RAx 50
4002951
RAx 75
4020384
RAx 100
4020384
RAx 125
4020384
RAx 150
4002954
RAx 200
4002956
RAx 250
4002956
RAx 300
4002958
RAx 350
4002958
RAx 400
4002961
RAx 500
4002961




• Anti-Corrosion
• Three-Valve Bypass
• Water Ingress Protection
For option compatibility, Please consult your MDI sales representative.





*Scroll to the right on mobile to see entire chart
DRYPOINT® RAx
H x W x D (inches)
Weight (lbs)
RAx 20
29 x 14 x 17
62
RAx 30
29 x 14 x 17
64
RAx 50
29 x 14 x 17
75
RAx 75
29 x 14 x 17
79
RAx 100
32 x 19 x 18
82
RAx 125
32 x 19 x 18
101
RAx 150
32 x 19 x 18
110
RAx 200
35 x 22 x 23
121
RAx 250
35 x 22 x 23
139
RAx 300
38 x 22 x 25
203
RAx 350
38 x 22 x 25
207
RAx 400
44 x 26 x 29
331
RAx 500
44 x 26 x29