DRYPOINT RA VSD Click for Larger View

Call us TODAY at 727-835-0670 or
Toll Free at 800-761-4298

Get A Free Quote!

BEKO DRYPOINT® RA VSD

• Required pre-filtration: 1 μm | Recommended post-filtration: .01 μm
• MODBUS ready
• Outlet pressure dew point: Class 4-5 in accordance with ISO 8573-1:2010
• Max. inlet air temperature: 160 °F
• Min. / max. ambient temperature: 34 °F / 115 °F
• Max. inlet pressure: 200 psig

Maintenance Interval:   < 8,000 hours
Maintenance Kits & Spare Parts

Click Here for Correction Factor Charts


Operating Pressure psig 60 80 100 120 140 160 180 200
Correction Factor .79 .91 1.00 1.07 1.13 1.18 1.23 1.27

Ambient Air Temperature °F 80 90 100 105 110 115 120
Correction Factor 1.11 1.09 1.00 .94 .87 .78 .69

Inlet Air Temperature °F 90 100 110 120 130 140 150 160
Correction Factor 1.16 1.00 .82 .68 .61 .52 .45 .40
The correction factors on this page provide an estimation of the performance that can be achieved with the model sizes shown. For precise sizing for your application, please contact your MDI sales representative.
AIR COOLED
*Scroll to the right on mobile to see entire chart
  Quantity Add to
Quote
DRYPOINT® RA VSD
Connection Size
(NPT)
Flow Rate
(scfm)
Power Consumption
at Full Load (kW)
Standard
Operating
Voltage
RA VSD 800
3" Flange
800
2.80
460 V / 3 Ph
RA VSD 1000
3" Flange
1000
4.10
460 V / 3 Ph
RA VSD 1250
3" Flange
1250
5.00
460 V / 3 Ph
RA VSD 1500
4" Flange
1500
5.80
460 V / 3 Ph
RA VSD 1750
4" Flange
1750
6.40
460 V / 3 Ph
RA VSD 2000
4" Flange
2000
8.00
460 V / 3 Ph
RA VSD 2500
4" Flange
2500
10.10
460 V / 3 Ph
RA VSD 3000
6" Flange
3000
11.20
460 V / 3 Ph
RA VSD 3750
6" Flange
3750
13.80
460 V / 3 Ph
RA VSD 4000
8" Flange
4000
15.40
460 V / 3 Ph
RA VSD 5000
8" Flange
5000
17.10
460 V / 3 Ph
RA VSD 6000
8" Flange
6000
22.30
460 V / 3 Ph

WATER COOLED
*Scroll to the right on mobile to see entire chart
  Quantity Add to
Quote
DRYPOINT® RA VSD
Connection Size
(NPT)
Flow Rate
(scfm)
Power Consumption
at Full Load (kW)
Standard
Operating
Voltage
RA VSD 800
3" Flange
800
2.80
460 V / 3 Ph
RA VSD 1000
3" Flange
1000
4.10
460 V / 3 Ph
RA VSD 1250
3" Flange
1250
5.00
460 V / 3 Ph
RA VSD 1500
4" Flange
1500
5.80
460 V / 3 Ph
RA VSD 1750
4" Flange
1750
6.40
460 V / 3 Ph
RA VSD 2000
4" Flange
2000
8.00
460 V / 3 Ph
RA VSD 2500
4" Flange
2500
10.10
460 V / 3 Ph
RA VSD 3000
6" Flange
3000
11.20
460 V / 3 Ph
RA VSD 3750
6" Flange
3750
13.80
460 V / 3 Ph
RA VSD 4000
8" Flange
4000
15.40
460 V / 3 Ph
RA VSD 5000
8" Flange
5000
17.10
460 V / 3 Ph
RA VSD 6000
8" Flange
6000
22.30
460 V / 3 Ph



*Scroll to the right on mobile to see entire chart
REQUIRED 1 μm PRE-FILTRATION
without Δpsi gauge | Float Drain
with Δpsi gauge | BEKOMAT®
RA VSD 800
4002903
4010403
RA VSD 1000
4002903
4010403
RA VSD 1250
4002903
4010403
RA VSD 1500
-
4020749
RA VSD 1750
-
4020749
RA VSD 2000
-
4020761
RA VSD 2500
-
4020761
RA VSD 3000
-
4020864
RA VSD 3750
-
4020864
RA VSD 4000
-
4012866
RA VSD 5000
-
4012866
RA VSD 6000
-
4012866

*Scroll to the right on mobile to see entire chart
OPTIONAL .01 μm POST-FILTRATION
Post-Filter | .01 μm
RA VSD 800
4002963
RA VSD 1000
4002963
RA VSD 1250
4002963
RA VSD 1500
4020750
RA VSD 1750
4020750
RA VSD 2000
4020762
RA VSD 2500
4020762
RA VSD 3000
4020865
RA VSD 3750
4020865
RA VSD 4000
4041302
RA VSD 5000
4041302
RA VSD 6000
4041302




For more options, Please consult your MDI sales representative.





*Scroll to the right on mobile to see entire chart
DRYPOINT® RA VSD
H x W x D (inches)
Weight (lbs)
RA VSD 800
58 x 31 x 39
534
RA VSD 1000
29 x 14 x 17
608
RA VSD 1250
58 x 31 x 39
686
RA VSD 1500
69 x 45 x 47
1,021
RA VSD 1750
69 x 45 x 47
1,202
RA VSD 2000
69 x 45 x 47
1,202
RA VSD 2500
69 x 45 x 47
1,349
RA VSD 3000
71 x 51 x 69
1,850
RA VSD 3750
71 x 51 x 69
2,090
RA VSD 4000
74 x 55 x 87
2,350
RA VSD 5000
74 x 55 x 87
2,670
RA VSD 6000
96 x 61 x 86
3,660